Electric Power EMCP 4.4 for Emergency Power Systems Brochure. Cat EMCP 4.4 controllers are designed for reliable genset operation with extensive information about power output and engine operation. From a single module to multiple units, these systems can be further customized to meet your specific needs. Download Now. Emcp 4.2 upgrade. The EMCP 4 CAN Annunciator serves to display genset system alarm conditions and status indications.The annunciator has been designed for use on the accessory communication network and may be used in either local (package mounted) or remote (up to 800 feet) application. A maximum of three annunciators may be used with a single EMCP 4.2B. Electric Power Generation: All Introduction. This Special Instruction will guide the user with step-by-step instructions for replacing a factory installed EMCP 3 with an EMCP 4.1 or an EMCP 4.2 and configuring an EMCP 4.1 or EMCP 4.2 on to a current production Caterpillar generator with an existing EMCP 3 installed. See Figure 1, showing the release date for an EMCP 4.2 flash file. Figure 1: EMCP Software Release Date Other product specific information and data is available from a variety of sources. For more information, contact the Cat dealer or dealer TC nearest you. Milton CAT D100-6S 100 kW EMCP4.2 EngineGen Control Panel User Manual. Optional modules, Emcp 4.2 generator set controller. Milton CAT Generators.
- Back Ups Es 650 User Manual Free
- Apc Back Ups Es 650 User Manual
- Back Ups 650 Manual
- Back Ups Es 650 User Manual Online
- Apc Back Ups 650 Manual
- Apc Back-ups Es 650 Manual
- Back Ups Es 650 User Manual Set Up Guide
Includes:USB cable, User Manual
![650 650](/uploads/1/2/6/4/126492439/652734255.jpg)
#BE650G1
Our Price: $89.00
Our Price: $89.00
Overview:
Back Ups Es 650 User Manual Free
Key Features:
- Battery failure notification
- Battery replacement without tools
- Disconnected battery notification
- Intelligent battery management
- LED status indicators
- Replace Battery LED
- USB connectivity
- User-replaceable batteries
The most popular desktop UPS in the world!
APC's Back-UPS® ES series is now 'greener' than ever. The ES 650 utilizes an ultra-efficient design that consumes less power during normal operation than any other battery backup in its class, saving you money on your electricity bill. It's also RoHS compliant, which means its manufacture and ultimate disposal is easier on the environment. Even the packaging has been carefully selected to minimize energy use in it's creation, and to maximize the use of recycled materials. Coupled with all the standard features of the Back-UPS ES series, the ES 650 is the best value for home and home office computers.
Features & Benefits:
Apc Back Ups Es 650 User Manual
Back-UPS ES 650 Battery Backup System Designed to use less energy during normal operation, this backup system provides enough power for you to work through short and medium length power outages. Data line protection safeguards your equipment from damaging surges. Panasonic liqi series user manual pdf. APC Back-UPS Pro® 280/420/650 User’s Manual 990-2037B Revision 3 12/97 Installation and Initial Start-Up To obtain warranty coverage, please fill out and return the warranty registration card now. Inspection Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it. RefurbUPS is the nation's most trusted source today for Performance Guaranteed power protection solutions. We supply more than 10,000 customers nationwide including today's leading corporations, retailers, government, and educational institutions. The Back-UPS ES is operating normally. The Back-UPS ES can only operate on battery power for a limited amount of time. The unit will eventually turn off when the available battery power has been used. Allow the unit to recharge for 16 hours before expecting maximum runtime. The output waveform is designed for computers and computer-related.
Protection | |
Battery failure notification | Provides early-warning fault analysis on batteries enabling timely preventive maintenance |
Power conditioning | Protects connected loads from surges, spikes, lightning, and other power disturbances. |
Dataline Surge Protection | Provides protection of connected equipment from power surges on the data lines. |
Lifetime data recovery warranty | Provides peace of mind with professional data recovery services in the event data is lost due to the failure of the unit (not available on all models). |
Safety-agency approved | Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. |
Convenience | |
Audible alarms | Provides notification of changing utility power and UPS conditions. |
Automatic self-test | Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
Cold-start capable | Provides temporary battery power when the utility power is out. |
Hot-swappable batteries | Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
Resettable circuit breakers | Enables quick recovery from UPS overload events. |
Transformer-block spaced outlets | Protect equipment with input transformer blocks without blocking access to other receptacles. |
Runtime Chart:
120V | |||||||||||
Watts | 50 | 100 | 200 | 300 | 400 | 500 | 600 | 700 | 800 | Full | Half |
VA~ | 80 | 160 | 320 | 480 | 640 | 800 | 960 | 1120 | 1280 | Load | Load |
BE350G | 16 min | 6 min | 1 min | - | - | - | - | - | - | 1 min (200 Watts) | 6 min (100 Watts) |
BE550G | 1 hrs 8 mins | 28 min | 10 min | 4 min | - | - | - | - | - | 3 min (330 Watts) | 13 min (165 Watts) |
BE650G1 | 1 hrs 5 mins | 29 min | 12 min | 6 min | - | - | - | - | - | 3 min (390 Watts) | 12 min (195 Watts) |
BE750G | 1 hrs 29 mins | 38 min | 14 min | 7 min | 4 min | - | - | - | - | 2 min (450 Watts) | 11 min (225 Watts) |
Technical Specifications:
Output | |
Output Power Capacity | 390 Watts / 650 VA |
Max Configurable Power | 390 Watts / 650 VA |
Nominal Output Voltage | 120V |
Output Frequency (sync to mains) | 60 Hz |
Waveform Type | Stepped approximation to a sinewave |
Output Connections | (4) NEMA 5-15R (Battery Backup) (4) NEMA 5-15R (Surge Protection) |
Required Output Current Protection | 15A |
Input | |
Nominal Input Voltage | 120V |
Input Frequency | 50/60 Hz |
Input Connections | NEMA 5-15P |
Cord Length | 6 feet (1.83 meters) |
Input voltage range for main operations | 88 - 139V |
Maximum Input Current | 12A |
Input Breaker Capacity | 15A |
Batteries & Runtime | |
Battery Type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof |
Typical recharge time | 24 hour(s) |
Replacement battery cartridge | RBC17 |
RBC™ Quantity | 1 |
Communications & Management | |
Interface Port(s) | USB |
Control Panel | LED status display with On Line : On Battery : Replace Battery and Building Wiring Fault |
Audible Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge Protection and Filtering | |
Surge Energy Rating | 365 Joules |
Filtering | Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 |
Dataline Protection | RJ-45 Modem/Fax/DSL/10-100 Base-T protection,Co-axial Video / Cable protection |
Physical | |
Maximum Height | 3.40 inches (86 mm) |
Maximum Width | 7.10 inches (180 mm) |
Maximum Depth | 11.20 inches (284 mm) |
Net Weight | 13.64 lbs. (6.20 kg) |
Shipping Weight | 15.40 lbs. (7.00 kg) |
Shipping Height | 5.00 inches (127 mm) |
Shipping Width | 8.90 inches (226 mm) |
Shipping Depth | 15.20 inches (386 mm) |
Color | Black |
SCC Codes | 1073130425652 3 |
Environmental | |
Operating Environment | 32 - 104°F (0 - 40°C) |
Operating Relative Humidity | 5 - 95% |
Operating Elevation | 0-10000 feet (0-3000 meters) |
Storage Temperature | 5 - 113°F (-15 - 45°C) |
Storage Relative Humidity | 5 - 95% |
Storage Elevation | 0-50000 feet (0-15000 meters) |
Audible noise at 1 meter from surface of unit | 45.00 dBA |
Online Thermal Dissipation | 15.00 BTU/hr |
Conformance | |
Regulatory Approvals | CSA C22.2 No. 107.1,FCC Part 15 Class B,FCC Part 68,NOM,TUV-C,UL 1778 |
Standard Warranty | 3 years repair or replace |
Equipment protection policy | Lifetime: $75,000 |
Environmental Compliance | RoHS,REACH: Contains No SVHCs |
**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.
Documentation:
Back Ups 650 Manual
Download the APC BE650G1 Data Sheet (PDF).
Pricing Notes:
- Pricing and product availability subject to change without notice.
- Note: Shipping charges may vary depending on the selected unit's weight or the quantity of units selected. As a result, the shipping charges may change from the value you receive at checkout. A customer representative will confirm these changes with you if they occur before processing your order.
Back Ups Es 650 User Manual Online
#BE650G1
Our Price: $89.00
Our Price: $89.00
Cables
Apc Back Ups 650 Manual
#AP9827
Our Price: $34.00
Our Price: $34.00
Extended Warranty & Service Agreements
Apc Back-ups Es 650 Manual
Please Note: Extended Warranties must be purchased before the termination date of the original factory warranty, Extended Warranties are non transferable. Some aspects of the service definition presented on this web site may vary by location. In the case of a conflict between the service definitions contained on this site and the local service definitions the local service definitions will prevail. For more information, please visit our services page.
Back Ups Es 650 User Manual Set Up Guide
Service Pack 1 Year Extended Warranty (for concurrent sales)
Service Pack 3 Year Extended Warranty (for concurrent sales)
#WEXTWAR1YR-SP-01
Our Price: $44.00
Our Price: $44.00
#WEXTWAR3YR-SP-01
Our Price: $89.00
Our Price: $89.00